Xgn66A-12 switch cabinet, combined AC metal-clad switch cabinet

Switchgear, Combined AC Metal-Clad Switchgear General:XGN66A-12 Combined and Fixed Indoor AC Metal-clad switchgear is a new generation of HV electric whole setproducts, which is complied with national standard GB3906 [3-35kV AC Metal-clad Switchgear] and thespecification of DL404 [Ordering technical condition of Indoor AC H

Featured Products

Switchgear, Combined AC Metal-Clad Switchgear
 
General:
XGN66A-12 Combined and Fixed Indoor AC Metal-clad switchgear is a new generation of HV electric whole set
products, which is complied with national standard GB3906 [3-35kV AC Metal-clad Switchgear] and the
specification of DL404 [Ordering technical condition of Indoor AC HV Switchgear] issued by Minister of
Electricity Power as well as IEC 298 [From 1kV to 52 kV AC Metal-clad Switchgear and Control equipment]. And
it has the closedown function of "Five production" put forward by Dept 2. This switchgear is suitable for three-
phase AC 50Hz, 3-10kV single sectioning busbar system used to distribute electric power. It has the function of
controlling, monitoring and protecting circuit. And it is wildly used in varieties of power plants, substation,
industrial and mining enterprise and high rise buildings as well as combined with RMU to be applied in the
switching stations.

Product feature:
A. Fitted in integer type vacuum circuit breaker, such as 12kV 3150A and 40kA;
B. A kind of specified designed switchgear in order to reduce occupied area of substation;
C. May combined with RMU randomly;
D. Simple but reliable machinery interlock for false protecting operation and easy operation;
E. The functional units are separated and fitted in separate pressure release passage to protect the
malfunction from enlarging and expanding;
F. Isolating distance and cable terminal contacts can be watched through the view window.

Ordering notice:
Please provide the followings:
A. Main wiring scheme code and single wire system diagram, pareto diagram and layout plan;
B. Secondary principle diagram, terminal pareto diagram. If not terminal pareto diagram, up to manufacturer's
standard;
C. Type, specification and quantity of electric components of switchgear;
D. Summary table of electric apparatus;
E. Please provide span and height dimensions if busbar bridge is needed ( between two switchgears or 
between switchgear and wall);
F. Please indicate if switchgear shall be in special condition;
G. Please indicate type and quantity of other accessories, if necessary.

Technical parameters:
ItemDescriptionUnit 
 
Value
1
 
Rated Voltage(MAX. Working Voltage)kV
 
12
 
2
 
Rated Insulating Lever 
 
1min Power Frequency  
Withstand 
 
kV
 
42
 
Lighting Impulse Withstand
 
kV
 
75
 
3
 
Rated Frequency
 
Hz
 
50
 
4
 
Rated Current for Primary Busbar
 
A
 
800
 
1250
 
2000 2500 3150
 
5
 
Rated Current for  Branch Busbar 
 
A
 
630
 
1000 1250
 
2000 2500 3150
 
6
 
4s Short-time Withstnd CurrentkA
 
20
 
31.5
 
40
 
7
 
Rated Peak Withstand Current 
 
kA
 
50
 
80
 
100
 
8
 
Protection Level
 
 
 
IP2X
 
9
 
Dimension
 
mm
 
900×900×2300
 
950×900×2300
 
1100×1000×2300
 
Xgn66A-12 Switchgear, Combined AC Metal-Clad Switchgear
Our Services
1.Pre sale service
a.make technical solution
b.send quotation, technical data sheet and drawing
c.prepare power transmission plan, testing plan,and shipment plan
2.In sale service
a.supervise the manufacturing schedule totally in accordance with the plan
b.send photos to customer during every manufacturing process(hold point)
c.inform the customer one week before testinng.
3.After sale service
a.installation and commissioning, training the workers
b.quick response within 12 hours any time
c.provide 12 months gurantee period normally.
 

FAQ
1. Q:What is your delivery time ?
A: Depend on the type of transformer.
2. Q:What is your payment term?
A: 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
3. Q:What kind of starndard you follow?
A: IEC, ANSI, CSA, GB, etc
4. Q:What kind of supporting documentation you can provide normally
A: Quotation,outline drawing,manufacturing plan, quality control plan
testing plan, financial report, type test report(KEMA, CESI),reference list,etc
5. Q:What is your normal wanrranty period?
A: 12 months after transformer operation.
6. Q:Can u do installation and commissioningin user's site?
A: Yes, we can send our installation team to user's country for service.
7. Q:Do you have any experience in this kind of transformer?
A: Yes, we can provide reference list for check.
8. Q:Are you manufacturer or trading company?
A: Manufacturer with own import & export company.
 
Our advantages:
Quality Assurance
--From the very beginning, VILLE ensures quality in every step to achieve the best quality.
 Experience Sharing
--With more than 30 years' experience in power industry, VILLE brings you an optimized solution.
 Global Service
--Wherever you are, VILLE global network will support and provide you with value.
 Quick Response
--In response to your needs without delay, VILLE  knows the value of your time.
 
Thanks for choosing VILLE as your reliable partner and
please trust both of us will create a brilliant future!

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours